What is EPA Type 1 Certification?
The EPA Type 1 certification covers Small Appliances. The EPA defines a small appliance as a product that is fully manufactured, charged, and hermetically sealed at the factory with 5 pounds (2.5 kg) or less of refrigerant.
Common examples include household refrigerators, freezers, room air conditioners (window units), vending machines, and water coolers. Getting your epa type 1 certification or epa type 1 license is essential for residential appliance repair.
Household refrigerators are the most common Type 1 appliance.
Interactive Type 1 Questions
Test your knowledge on small appliances.
Key Topic 1: Recovery Requirements
For small appliances, you don't need to pull a specific vacuum level (like 10 inches Hg). Instead, the EPA sets recovery efficiency percentages based on the compressor's condition. You must memorize this for the epa type 1 practice test.
of refrigerant must be recovered.
(Or pull 4 inches of Hg vacuum)
of refrigerant must be recovered.
(Or pull 4 inches of Hg vacuum)
Key Topic 2: Recovery Techniques
Type 1 introduces a unique method called System-Dependent (Passive) Recovery. This captures refrigerant into a non-pressurized container/bag using the appliance's own compressor, rather than an external machine.
Passive Recovery Tips:
- Run the Compressor: If operational, use it to pump refrigerant into the recovery bag.
- Heat & Tap: If the compressor is dead, heat the oil/compressor and tap it with a mallet to release trapped refrigerant.
- Access Points: You must access both the high and low sides of the system to ensure full recovery if the compressor is broken.
Key Topic 3: Access Valves
Small appliances typically don't have service ports. Technicians use piercing access valves (bullet valves) to connect gauges.
- Fitting Type: These fit onto copper or aluminum tubing.
- Leak Risk: Piercing valves tend to leak over time. They must not be left on the system permanently. Use them only for service/recovery and then remove/braze the hole.
- Solderless: Solderless access fittings are convenient but prone to leaks.
Key Topic 4: Safety & Decomposition
At high temperatures (like from a soldering torch), refrigerants decompose into toxic chemicals.
- Phosgene Gas: Formed when CFCs/HCFCs touch an open flame. It is deadly.
- Hydrochloric/Hydrofluoric Acid: Also formed during decomposition.
- Ventilation: Always work in a well-ventilated area to avoid asphyxiation, as refrigerant is heavier than air and displaces oxygen.
Type 1 FAQs
No. Piercing valves are for temporary service only. They tend to leak and should be removed after recovery or repair.
No. Even if a split system holds less than 5 lbs (like some mini-splits), it falls under Type 2 because it is not factory sealed/hermetic.
It depends. If it is a small, factory-sealed appliance (like a fridge), yes. If it's a dashboard motor vehicle AC, that is Section 609, not Type 1.
If you cannot verify the 80%/90% recovery by weight, you can simply evacuate the system to 4 inches of Mercury (Hg) vacuum.
Explore Other Sections